dc.identifier.citationFARIAS, Lidianne do Nascimento. Influência da composição do concreto e dos parâmetros de ensaio na resistividade elétrica obtida pelo método direto. 2020. 112 f. Dissertação (Mestrado em Engenharia Civil e Ambiental)- Universidade Estadual de Feira de Santana, Feira de Santana, 2020.por
dc.identifier.urihttp://tede2.uefs.br:8080/handle/tede/1225-
dc.description.resumoA resistividade elétrica é vista como um parâmetro de verificação da durabilidade em estruturas, pois indica a resistência do concreto quanto à penetração de agentes agressivos. Além do que, considerando-se um método não destrutível, pode-se tornar bastante útil sua utilização. Porém, tal propriedade pode ser influenciada por diversos fatores. Nesse contexto, o presente estudo avaliou o comportamento da resistividade elétrica devido alterações de composição das misturas (tipos de cimento, relações água/cimento e teores de brita) e quanto aos parâmetros de ensaio (teor de umidade, dimensão da amostra, idade e níveis de fissuração). A resistividade elétrica do concreto foi obtida através do Método Direto, conforme procedimentos da norma espanhola UNE 83988-1 (AENOR, 2008). Os resultados apontaram que a resistividade elétrica dos concretos aumentou com o tipo de cimento CPV-ARI, com o acréscimo no teor de agregado graúdo e com a redução da relação a/c. Em relação a dimensão dos corpos de prova e do seu grau de umidade, a redução desses parâmetros ocasionou um aumento substancial na resistividade dos concretos. Os níveis de fissuração mostraram que fissuras não visíveis sugerem uma baixa variação na resistividade quando aplicado níveis de tensão aos espécimes. Por fim, este trabalho determina valores de referência quanto à exposição do concreto aos níveis de corrosão, propondo o Método Direto como forma de avaliação da resistividade elétrica dos concretos.por
dc.description.abstractElectrical resistivity is seen as a parameter for verifying durability in structures, as it indicates the strength of concrete in terms of penetration by aggressive agents. In addition, considering it a non-destructive method, its use can be quite useful. However, this property can be influenced by several factors. In this context, the present study evaluated the behavior of electrical resistivity due to changes in the composition of mixtures (types of cement, water/cement ratios and gravel contents) and in terms of test parameters (moisture content, sample size, age and levels cracking). The electrical resistivity of the concrete was obtained through the Direct Method, according to the procedures of the Spanish standard UNE 83988-1 (AENOR, 2008). This test method has characteristics that have not been much investigated by the brazilian scientific community. The results showed that the electrical resistivity of the concrete increased with the type of cement CPV-ARI, with the increase in the content of coarse aggregate and with the reduction of the a/c ratio. Regarding the size of the specimens and their degree of humidity, the reduction of these parameters caused a substantial increase in the resistivity of the concretes. Cracking levels showed that invisible cracks suggest a low variation in resistivity when stress levels are applied to specimens. Finally, this work determines reference values regarding the exposure of concrete to corrosion levels, proposing the Direct Method as a way of evaluating the electrical resistivity of concrete.eng
dc.description.provenanceSubmitted by Ricardo Cedraz Duque Moliterno (ricardo.moliterno@uefs.br) on 2021-03-17T21:37:20Z No. of bitstreams: 1 DISSERTACAO_LIDIANNE_FARIAS_18_02_2020.pdf: 3310282 bytes, checksum: 4c3f5f4a59a320be57352df5f063d39b (MD5)eng
dc.description.provenanceMade available in DSpace on 2021-03-17T21:37:20Z (GMT). No. of bitstreams: 1 DISSERTACAO_LIDIANNE_FARIAS_18_02_2020.pdf: 3310282 bytes, checksum: 4c3f5f4a59a320be57352df5f063d39b (MD5) Previous issue date: 2020-02-18eng
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado da Bahia - FAPEBpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Estadual de Feira de Santanapor
dc.publisher.departmentDEPARTAMENTO DE TECNOLOGIApor
dc.publisher.countryBrasilpor
dc.publisher.initialsUEFSpor
dc.publisher.programMestrado em Engenharia Civil e Ambientalpor
dc.rightsAcesso Abertopor
dc.subjectDurabilidadepor
dc.subjectResistividade elétricapor
dc.subjectMétodo diretopor
dc.subjectDurabilityeng
dc.subjectElectrical resistivityeng
dc.subjectDirect methodeng
dc.subject.cnpqCONSTRUCAO CIVIL::MATERIAIS E COMPONENTES DE CONSTRUCAOpor
dc.subject.cnpqENGENHARIA CIVIL::CONSTRUCAO CIVILpor
dc.titleInfluência da composição do concreto e dos parâmetros de ensaio na resistividade elétrica obtida pelo método diretopor