???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: http://tede2.uefs.br:8080/handle/tede/794
Full metadata record
DC FieldValueLanguage
dc.creatorJesus, Thiago Barbosa-
dc.creator.Latteshttp://lattes.cnpq.br/9872147700635568por
dc.contributor.advisor1Silva, Eduardo Henrique Borges Cohim-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/5568291552653842por
dc.date.accessioned2019-07-15T22:36:18Z-
dc.date.issued2018-09-05-
dc.identifier.citationJESUS, Thiago Barbosa. Alocação eficiente de fontes de água em uma residência. 2018. 89f. Dissertação (Mestrado em Engenharia Civil e Ambiental) - Universidade Estadual de Feira de Santana, Feira de Santana, 2018.por
dc.identifier.urihttp://tede2.uefs.br:8080/handle/tede/794-
dc.description.resumoEste estudo está estruturado em quatro artigos-capítulos dedicados a identificação e minimização da Intensidade Energética (IE) no abastecimento de água. No primeiro artigo objetivou-se encontrar a IE de Sistemas de Aproveitamento de Água de Chuva (SAAC).Os resultados demonstraram a existência de um ótimo energético entre os volumes de reservatórios de 1,0∙10³ L a 2,5∙10³ L, para as áreas de captação testadas com demanda igual de 4,8∙10² L∙(residência∙dia)-1. O desempenho energético calculado ficou de 0,51 kWh∙m-3 a 0,90 kWh∙m-3. Para o valor médio de área de captação de 80 m² a IE mínima foi de 0,72 kWh∙m-3 com reservatório de 1,75∙10³ L. O segundo artigo explorou diferentes materiais para os diversos componentes do SAAC, incluindo a calha, reservatório e fonte de energia. Destes o mais relevante foi o reservatório, seguido da calha e fonte de energia. A configuração menos intensiva foi o uso do reservatório de polietileno, a calha de alumínio e energia fotovoltaica, neste cenário a IE calculada foi de 0,66 kWh∙m-3. Os resultados obtidos neste artigo mostraram a importância da escolha dos componentes dos SAAC, que afetam diretamente a IE final. No terceiro artigo foi avaliado o aproveitamento da água subterrânea com profundidades variando de 5 m a 25 m, sendo encontradas IE de 1,74 kWh∙m-3 a 2,97 kWh∙m-3.O revestimento do poço e a bomba foram os componentes mais intensivos, com participação superior a 70% em todas as profundidades. Nos três artigos elaborados a IE encontrada foi inferior à do sistema público de abastecimento e a fase de implantação foi a que mais contribuiu para a IE final. Este resultado mostra a importância na escolha dos componentes dos sistemas descentralizados de abastecimento, que estes afetam diretamente a IE. O quarto artigo buscou encontrar o melhor arranjo de fornecimento de água que propicie o menor encargo energético associado a água de abastecimento de uma residência. Foram utilizados os valores encontrados nos artigos elaborados no âmbito desta dissertação, complementados com dados de IE da água cinza encontrada em literatura. O mix de água do sistema público, água de chuva, subterrânea e cinza resultaria no encargo energético de 2,44 kWh∙m-3, para o abastecimento de uma residência com quatro pessoas no município de Feira de Santana/BA. Esse valor representaria uma redução de 31% da IE em relação ao sistema público e de 72% do consumo da água do sistema públicopor
dc.description.abstractThis study is structured in four chapters-articles dedicated to identify and minimize the Energy Intensity (EI) of water supply. In the first article we aimed to find the EI of Rainwater Harvesting Systems (RWHS). The results showed the existence an optimal point between the reservoir volumes from 1.0∙10³ L to 2.5∙10³ L, adopting the catchment areas tested with equal demand of 4.8∙10² L∙(residence∙day)-1. The calculated energy performance was 0.51 kWh∙m-3 at 0.90 kWh∙m-3. For the mean value of catchment area of 80 m² the minimum EI was 0.72 kWh∙m-3 with a reservoir of 1.75∙10³ L. The second article explored different materials for the various RWHS components, including the gutter, reservoir and energy source. Beteween these components, the most relevant was the reservoir, followed by gutter and energy source. The least intensive configuration was the use of the polyethylene reservoir, the aluminum gutter and photovoltaic energy, for this scenario the calculated EI was 0.66 kWh∙m-3. The results obtained in this article showed the importance of choosing materials for RWHS, which directly affect the final EI. In the third article we evaluated the use of groundwater with depths ranging from 5 m to 25 m, with EI from 1.74 kWh∙m-3 to 2.97 kWh∙m-3. The well casing and the pump were the most intensive components, with more than 70% participation at all depths. In the three articles elaborated the EI found was lower than the public supply system and the construction phase was the one that mostcontributed to the final EI. This result shows the importance for the choosing components of decentralized supply systems, that these directly affect EI. The fourth article sought to find the best water supply arrangement that would provide the least EI associated with the water supply of a residence. The values found in the articles elaborated within this dissertation were used, complemented with EI data of gray water found in the literature. The public water, rainwater, underground and gray water mix would result in an EI of 2.44 kWh∙m-3 for the supply of a residence with four people in the municipality of Feira de Santana/BA. This figura would represent a reduction of 31% of EI in relation to the public system and 72% of the water consumption of the public systemeng
dc.description.provenanceSubmitted by Verena Pereira (verenagoncalves@uefs.br) on 2019-07-15T22:36:18Z No. of bitstreams: 1 Dissertação-Thiago-Barbosa_R0.pdf: 1897472 bytes, checksum: e8d58a0acf3cf03bab2b40dbb23b3da1 (MD5)eng
dc.description.provenanceMade available in DSpace on 2019-07-15T22:36:18Z (GMT). No. of bitstreams: 1 Dissertação-Thiago-Barbosa_R0.pdf: 1897472 bytes, checksum: e8d58a0acf3cf03bab2b40dbb23b3da1 (MD5) Previous issue date: 2018-09-05eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Estadual de Feira de Santanapor
dc.publisher.departmentDEPARTAMENTO DE CIÊNCIAS EXATASpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUEFSpor
dc.publisher.programMestrado em Engenharia Civil e Ambientalpor
dc.rightsAcesso Abertopor
dc.subjectAvaliação do Ciclo de Vidapor
dc.subjectFontes de abastecimentopor
dc.subjectSistema descentralizadospor
dc.subjectIntensidade energéticapor
dc.subjectLife Cycle Assessmenteng
dc.subjectsources of supplyeng
dc.subjectdecentralized systemeng
dc.subjectenergy intensityeng
dc.subject.cnpqENGENHARIA SANITARIA::SANEAMENTO AMBIENTALpor
dc.titleAlocação eficiente de fontes de água em uma residênciapor
dc.typeDissertaçãopor
Appears in Collections:Coleção UEFS

Files in This Item:
File Description SizeFormat 
Dissertação-Thiago-Barbosa_R0.pdfDissertação_Thiago_20181.85 MBAdobe PDFDownload/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.